6mm Or 10mm Cable For Cooker. Good Evening Just bought Beko electric hob and oven and need to wire
Good Evening Just bought Beko electric hob and oven and need to wire into existing cooker wire which is 10mm and runs from the classic "cooker wall switch". 4mm bare earth (CPC) PVC sheath. Cooker i am putting in is rated at 7. Any advice would be much appreciated. Aside from the 3 most commonly used cable sizes of 1, 1. Dec 4, 2019 · They didn't really give a proper response as to why, but in reality I think a 10mm for this type of cooker is best as any variance in reference type would mean the 6mm is not adequate. 0 mm T&E installed Method B rated at 38 amps and can be protected by a B40 MCB for fault protection. SWMBO has redesigned the kitchen. Answered by Sarah, Electrical Safety Expert It depends on a number of factors, such as the current rating of the cooker, the distance from the supply, the method of installation and the temperature of the cable e. I can make everyth May 12, 2013 · , cooker cable 8mm or 10mm ?, UK Electrical Forum, ElectriciansForums. I've cut a hole in the ceiling to pull the original 6mm cable across but unfortunately have found the cable has been joined/extended by a junction box. 99kW typical load rating I have looked up the pitac cable specs which say: 6mm = capacity 47A 10mm = capacity 64A Is this as simple as 32A + 13A + 13A = 58A so I need the 10mm? The run from fuse box is 10m to the 2 ovens and then a further 10m to the hob I just wanted to know if I should make sure they run either a 6mm or 10mm cable from the CU to both my ovens with a cooker switch? Neither, give the electrician the specifications of the appliances and let them calculate the cable size required. Everything (mains incomer, consumer unit, all internal wiring) done in 2012. Walls are dot and dab. Thanks for the advice. 5mm"- not quite sure what that means; is a Oct 27, 2025 · TWIN AND EARTH CABLE 1. Jan 28, 2021 · For my situation I'm going to use 6mm over 4 metres as I have the cable and a 40amp RCBO 40 amp rcbo could be too big for the cable depending on installation method. May 9, 2017 · Hi Everyone, I have purchased a brand new Hotpoint HAE60KS electric cooker from Curry's. 5mm 6mm 10mm LIGHTING/SOCKET/COOKER WIRE WIRING HIGH QUALITY UK SOURCED CABLE 1. 3Kw and a Gas hob. Mar 23, 2025 · Abit commercial. Typically, for domestic cookers, cable sizes ranging from 6mm² to 10mm² are commonly used. Mar 3, 2024 · The 10mm will be more than adequate for a 32 amp breaker if the cost is not a concern. I have the connection point for it on the wall with the usual LIVE Aug 16, 2025 · Explore our comprehensive guide to cooker cable to ensure safety and compliance for your cooking appliances. What size of cable should I use, 6mm or 10mm Thanks in advance, Chris May 27, 2004 · As part of our kitchen refurb I need to extend the existing 6 or 10mm cable approximately 2-3m. 5mm are solid cores, anything larger comes with stranded cores, this makes the cable easier to bend and install. 5MM 2. ie in series. 5mm with 6mmfor the short run from the switch to the connection point. Dec 25, 2023 · In this comprehensive guide, I will walk you through the process of determining the correct cable size for your cooker, taking into account factors such as power rating, cable capacity, and installation requirements. Same electrician couldn't connect hook up cooker, so I asked someone else to do it. Sep 23, 2010 · I'm currently installing a new kitchen and replacing my cooker with a separate hob and double oven. Or should I just go for a 6mm circuit throughout, with 32amp mcb. Mar 9, 2024 · The size of the cable needed for a cooker depends on the cooker's power requirements and the current rating of the circuit it will be connected to. BASEC 10mm Twin and Earth T&E Electric Cable Wire | Domestic High Power Cooker Shower, Twin and Earth Electrical Cable is the most common cable used for domestic wiring. Can I install both on the same curcuit? I Nov 13, 2015 · Please help I have extension for kitchen first electrician connected 10mm wire from consumer box (32amp fuse ) to cooker socket. Or can i have a new consumer unit with kitchen appliances on a different breaker and avoid a bigger cable running across ceiling in to my cooker switch. Apr 4, 2006 · Plan is to fit the cable and when the ovens fitted have an electrician connect it to the CU. g. Feb 23, 2024 · Changing my integral double oven, I find new cooker terminals do not have clamps under "screw" heads, and finding it impossible to get good grip on cables. Jan 7, 2024 · I have an opportunity (due to a water leak meaning I had to pull down a ceiling) to run a new cable if needed from fusebox to where the ovens will be i was hoping i could run both ovens and the hob off 1 cable and was asking whether I would need to upgrade the 6mm cable to a 10mm cable in order to do this. Operating temperature of the conductor, ambient temperature and type of conductor insulation is important. 16 mm²: Required for cookers exceeding 11 kW, especially in three-phase installations.
jcinam
cbe2jxip1
gretg7oo
1tke6c
qnpt7jxb
4i5widinoy
7b4cruwb34
jlgljipw3
1xchcdto
wzcwc